TempRecord Directions
Download TempRecord 5.25
Download TempRecord 5.15
| All Setting Up options are contained in the Options menu. presented as tabbed pages. |
| Across the top of the screen are displayed the five main groups of functions. |
| Open each by clicking with mouse File. Program, View, Options and Help |
| 1. Open Options menu and click on "General" |

1. Click "Fahrenheit" Click all "Prompts" except "Use short filenames" Click "OK"

| 2. Open Options menu and click on "COM Port" |
| 3. Click "Use this COM Port" when using 232 Reader connection OR |
|
| Click "Look for USB Reader" when using USB Reader connection Click "OK" |

| 1. Click " Program" Click " Stop Logger" If error message received: |

2. Click "Re-use Logger" If error message received:

3. Click "Parameters"

| . Input Recorder Start Date and Breeder Age @ Start - DO NOT ENTER PASSWORD |
| 5. Input 15 minutes in Sample Period - Input :10 seconds in Start Delay |
| 6. Input Upper Limit Target Degrees - Input Lower Limit Target Degrees |
| 7.Click "Loop Overwrite""Start with button" & "Allow Markers" in Enables All other boxes must be Blank! |
| 8.Click "OK"- Press"Start Button" on logger placed - Note start flashing light |

| 1. Open Options menu and click on "Statistics" |
| 2. Check "Show TTV Statistics" & "Show Brief TTV Statistics Only" |
| 3. Place in "Lower & Upper" limits for each age of production. (7 or 16 periods) |
| 4. Place in "Period Duration 1:00" - Place in "Periods to Show" (7 or 16 periods) |
Export Directions